Product Name | CAP - 18, rabbitGLRKRLRKFRNKIKEKLKKIGQKIQGLLPKLAPRTDY |
Size | 0.5 mg |
Catalog # | AS-61307 |
US$ | $238 |
Purity | % Peak Area By HPLC ≥ 95% |
This 37 residue peptide is a very effective antimicrobial agent in rabbits. The CAP-18 cathelicidin-derived peptide kills bacteria by disrupting the bacterial membrane. It has a potential for the treatment of bacterial infections in normal and immunocompromised persons and individuals with cystic fibrosis. In experiments it demonstrates the greatest activity against over 20 clinical strains of Pseudomonas aeruginosa. Homologs of CAP18in other species include humans (FALL39/LL37), mice (mCRAMP), rats (rCRAMP), and sheep (SMAP29 and SMAP34). | |
Detailed Information | Material Safety Data Sheets (MSDS) |
Storage | -20°C |
References | Travis, S et al. Infect. Immun. 68, 2748 (2000). |
Molecular Weight | 4433.5 |
GLRKRLRKFRNKIKEKLKKIGQKIQGLLPKLAPRTDY | |
Sequence(Three-Letter Code) | H - Gly - Leu - Arg - Lys - Arg - Leu - Arg - Lys - Phe - Arg - Asn - Lys - Ile - Lys - Glu - Lys - Leu - Lys - Lys - Ile - Gly - Gln - Lys - Ile - Gln - Gly - Leu - Leu - Pro - Lys - Leu - Ala - Pro - Arg - Thr - Asp - Tyr - OH |
ebiomall.com
>
>
>
>
>
>
>
>
>
>
>
>
2005年第145号
为进一步贯彻实施《中华人民共和国计量法》、《中华人民共和国行政许可法》,我局组织制定了“中华人民共和国依法管理的计量器具目录(型式批准部分)”,现予以公布,自2006年5月1日起施行。列入“中华人民共和国依法管理的计量器具目录(型式批准部分)”的项目要办理计量器具许可证、型式批准和进口计量器具检定。
实施强制检定的工作计量器具目录按现有规定执行。专用计量器具目录由国务院有关部门计量机构拟定,报我局审核后另行公布。医用超声源、医用激光源、医用辐射源的管理按“关于明确医用超声、激光和辐射源监督管理范围的通知”(技监局量发[1998]49号)执行。
自即日起,未列入本目录的计量器具,不再办理计量器具许可证、型式批准和进口计量器具检定。
附件:中华人民共和国依法管理的计量器具目录(型式批准部分)
二〇〇五年十月八日
附件:
中华人民共和国依法管理的计量器具目录(型式批准部分)
1. 测距仪:光电测距仪、超声波测距仪、手持式激光测距仪;
2. 经纬仪:光学经纬仪、电子经纬仪;
3. 全站仪:全站型电子速测仪;
4. 水准仪:水准仪;
5. 测地型GPS接收机:测地型GPS接收机;
6. 液位计:液位计;
7. 测厚仪:超声波测厚仪、X射线测厚仪、电涡流式测厚仪、磁阻法测厚仪、γ射线厚度计;
8. 体温计:测量人体温度的红外温度计(红外耳温计、红外人体表面温度快速筛检仪);
9. 辐射温度计:工作用全辐射感温器、工作用辐射温度计、500℃以下工作用辐射温度计;
10. 天平:非自动天平;
11. 非自动衡器:非自动秤、非自行指示轨道衡、数字指示轨道衡;
12. 自动衡器:重力式自动装料衡器、连续累计自动衡器(皮带秤)、非连续累计自动衡器、动态汽车衡(车辆总重计量)、动态称量轨道衡、核子皮带秤;
13. 称重传感器:称重传感器;
14. 称重显示器:数字称重显示器;
15. 加油机:燃油加油机;
16. 加气机:液化石油气加气机、压缩天然气加气机;
17. 流量计:差压式流量计、速度式流量计、液体容积式流量计、转子流量计、靶式流量变送器、临界流流量计、质量流量计、气体层流流量传感器、气体腰轮流量计、明渠堰槽流量计;
18. 水表:冷水表、热水表;
19. 燃气表:膜式煤气表;
20. 热能表:热能表;
21. 风速表:轻便三杯风向风速表、轻便磁感风向风速表、电接风向风速仪;
22. 血压计和血压表:血压计、血压表;
23. 眼压计:压陷式眼压计;
24. 压力仪表:弹簧管式精密压力表和真空表、弹簧管式一般压力表、压力真空表和真空表、膜盒压力表、记录式压力表、压力真空表及真空表、轮胎压力表、压力控制器、数字压力计;
25. 压力变送器和压力传感器:压力变送器、压力传感器;
26. 氧气吸入器:浮标式氧气吸入器;
27. 材料试验机:摆锤式冲击试验机、悬臂梁式冲击试验机、轴向加荷疲劳试验机、旋转纯弯曲疲劳试验机、拉力、压力和万能试验机、非金属拉力、压力和万能试验机、电子式万能材料试验机、木材万能试验机、抗折试验机、杯突试验机、扭转试验机、高温蠕变、持久强度试验机;
28. 振动冲击测量仪:工作测振仪、公害噪声振动计、冲击测量仪、基桩动态测量仪;
29. 测速仪:机动车雷达测速仪、定角式雷达测速仪;
30. 出租汽车计价器:出租汽车计价器;
31. 接地电阻测量仪器:接地电阻表、接地导通电阻测试仪;
32. 绝缘电阻测量仪:绝缘电阻表(兆欧表)、高绝缘电阻测量仪(高阻计);
33. 泄漏电流测量仪:泄漏电流测量仪(表);
34. 耐电压测试仪:耐电压测试仪;
35. 电能表:交流电能表、电子式电能表、分时计度(多费率)电能表、最大需量电能表、直流电能表;
36. 测量互感器:测量用电流互感器、测量用电压互感器;
37. 电阻应变仪:电阻应变仪;
38. 场强测量仪:干扰场强测量仪、近区电场测量仪;
39. 微波辐射与泄漏测量仪:微波辐射与泄漏测量仪;
40. 心脑电测量仪器:心电图机、脑电图机、脑电地形图仪、心电监护仪;
41. 电话计时计费器:单机型和集中管理分散计费型电话计时计费器、IC卡公用电话计时计费装置;
42. 噪声测量分析仪器:声级计、噪声剂量计、噪声统计分析仪、个人声暴露计、倍频程和1/3倍频程滤波器;
43. 听力计:纯音听力计、阻抗听力计;
44. 医用超声源:超声多普勒胎儿监护仪超声源、医用超声诊断仪超声源、医用超声治疗机超声源、超声多普勒胎心仪超声源;
45. 焦度计:焦度计;
46. 验光机:验光机;
47. 照度计:紫外辐射照度计、光照度计;
48. 医用激光源:医用激光源;
49. 活度计:放射性活度计、用152Eu点状γ标准源校准锗γ谱仪、低本底α、β测量仪、α、β和γ表面污染仪、γ放射免疫计数器;
50. 环境与防护剂量(率)计:环境监测用X、γ辐射热释光剂量测量装置、环境监测用X、γ辐射空气吸收剂量率仪、辐射防护用X、γ辐射剂量当量(率)仪和监测仪、直读式验电器型个人剂量计、个人监测用X、γ辐射热释光剂量测量装置、X、γ辐射个人报警仪、中子周围剂量当量测量仪;
51. 剂量计:治疗水平电离室剂量计、γ射线水吸收剂量标准剂量计(辐射加工级)、γ射线辐射加工工作剂量计、电子束辐射加工工作剂量计;
52. 医用辐射源:外照射治疗辐射源、医用诊断X辐射源、医用诊断计算机断层摄影装置(CT)X射线辐射源、γ射线辐射源(辐射加工用);
53. 测氡仪:测氡仪;
54. 热量计:氧弹热量计、水流型气体热量计、示差扫描热量计;
55. 糖量计:手持糖量计、手持折射仪;
56. 电导仪:电导仪;
57. pH计:实验室pH(酸度)计、船用pH计;
58. 分光光度计:可见分光光度计、单光束紫外-可见分光光度计、原子吸收分光光度计、双光束紫外可见分光光度计、荧光分光光度计、色散型红外分光光度计、紫外、可见、近红外分光光度计、全差示分光光度计;
59. 光谱仪:发射光谱仪、波长色散X射线荧光光谱仪;
60. 旋光仪:旋光仪、旋光糖量计;
61. 色谱仪:气相色谱仪、液相色谱仪、离子色谱仪、凝胶色谱仪;
62. 浊度计:浊度计;
63. 烟尘粉尘测量仪:烟尘测试仪、粉尘采样器、光散射式数字粉尘测试仪;
64. 总悬浮颗粒物采样器:总悬浮颗粒物采样器;
65. 大气采样器:大气采样器;
66. 水质分析仪:覆膜电极溶解氧测定仪、水中油份浓度分析仪、化学需氧量(COD)测定仪、氨自动分析仪、生物化学需氧量(BOD5)测量仪、硝酸根自动监测仪、总有机碳分析仪、离子计;
67. 有毒有害气体检测(报警)仪:二氧化硫气体检测仪、硫化氢气体分析仪、一氧化碳检测报警器、一氧化碳、二氧化碳红外线气体分析器、烟气分析仪、化学发光法氮氧化物分析仪;
68. 易燃易爆气体检测(报警)仪:可燃气体检测报警器、光干涉式甲烷测定器、催化燃烧式甲烷测定器、催化燃烧型氢气检测仪;
69. 汽车排放气体测试仪:汽车排放气体测试仪;
70. 烟度计:滤纸式烟度计、透射式烟度计;
71. 测汞仪:测汞仪;
72. 水分测定仪:烘干法谷物水分测定仪、电容法和电阻法谷物水分测定仪、原棉水分测定仪;
73. 呼出气体酒精含量探测器:呼出气体酒精含量探测器;
74. 光度计:火焰光度计、非色散原子荧光光度计;
75. 血细胞分析仪:血细胞分析仪
建议查下资料哦
感觉提问主意不是很清晰
CSY-E96D动物疾病快速诊断仪采用固相酶联免疫吸附ELISA的原理、检验检疫单位使用,广泛应用于养殖场,即酶联免疫法、屠宰场、肉产品深加工企业、猪瘟、猪蓝耳。2着都是利用酶联免疫吸附法ELISA试剂取检测的
光较强的孔就会干扰相邻的孔。因此,化学发光测试一般不用透明微孔板
96孔不透明的白板(化学发光用的)
是将具有高灵敏度的化学发光测定技术与高特异性的免疫反应相结合,用于各种抗原、半抗原、抗体、激素、酶、脂肪酸、维生素和药物等的检测分析技术。是继放免分析、酶免分析、荧光免疫分析和时间分辨荧光免疫分析之后发展起来的一项最新免疫测定技术。
化学发光免疫分析包括三大类型:即标记化学发光物质的化学发光免疫分析;标记荧光物质的荧光化学发光免疫分析和标记酶的化学发光酶联免疫分析。下面以偶合放大化学发光酶联免疫分析法检测人血清中乙型肝炎表面抗原(HBsAg)为例。
(一) 原理
尽管辣根过氧化物酶(HRP)可以催化Luminol-H2O2反应体系产生化学发光,但由于该体系的检测灵敏度不够高,不能满足酶联免疫测定的要求。因此,为了提高体系的检测灵敏度,可将HRP催化H2O2氧化曙红(Eosin)的反应与该反应产物增强HRP催化luminol-H2O2的化学发光反应相偶合,建立偶合放大化学发光酶联免疫分析法。这里,酶的活性是基于下列发光反应进行检测的:
HRP
luminol+H2O2───→产物+hν
产 物
↑
Eosin+H2O2──────┘
HRP
二) 操作步骤
1. 包被抗体 在每个小试管中加入聚苯乙烯珠各一枚,再加入300μl用0.05M,PH9.6碳酸盐缓冲液稀释的抗HBsAg抗体,同时设空白对照,置4℃过夜。
2. 洗涤 用抽滤针头吸干管内液体,加入Tris-HCl-Tween20洗涤3次,每次加2ml,放置3~5min,用抽滤针头吸干管内液体。
3. 加待检血清和阳性标准品 用PBS-Tween20缓冲液不同倍数稀释HBsAg阳性标准品或待检血清,每管加入300μl。同时设阴性对照;空白对照管只加抗体稀释液。置37℃孵育2h。
4. 洗涤 同2。
5. 加酶标抗体 用含小牛血清的PBS-Tween20缓冲液稀释HRP标记的抗HBsAg抗体,每管加入300μl,空白对照管只加用于稀释酶标抗体的稀释液。置37℃孵育2h。
6. 洗涤 同2。
7. 化学发光测定 给每管加入300μl底物溶液,置37℃保温20min。犎;后将小试放入LKB-1250lumimeter中,并置于测量位置,加入300μl5.0×10-4Mluminol。记录仪记录化学发光强度。
8. 同时用ELISA方法进行对照,结果测量采用DG3022型酶联免疫检测仪。
结果判定
(1) 定性 按下列公式判别阴、阳性:
L样品-L空白 ┌≥2.1 为阳性
S/N=──────── = 商│
L阴性对照-L空白 └<2.1 为阴性
(2) 定量 以不同稀释度的HBsAg阳性标准品的化学发光强度为纵坐标,不同稀释倍数为横坐标,作出剂量反应曲线(标准曲线),犜r待测样品中HBsAg的含量就可由测量的化学发光强度换算得到。
(三) 试剂和器材
1. 试剂
(1) 缓冲液 a. 0.05M,PH9.6Na2CO3-NaHCO3缓冲液(包被液)
b.0.01M,PH7.4PBS-Tween20缓冲液(抗体稀释液)
c.0.02M,PH7.4Tris-HCl-Tween20缓冲液(洗涤液)
(2) 抗体 a.抗HBsAg抗体
b.HRP标记的抗HBsAg抗体
(3) 抗原 a.正常人血清(HBsAg阴性对照)
b.HBsAg阳性标准品
c.待检血清
(4) 小牛血清
(5) 底物溶液
1.0mlEDTA(1.0×10-2M)
2.0mlEosin(1.0×10-3M)
1.0mlH2O2(7.5×10-3M) 用三蒸水稀释到25ml
0.4mlHCl(1.0×10-2M)
0.2mlTween20(1%)
(6) luminol5.0×10-4M
2. 器材
(1) LKB-1250lumimeter
(2)隔水式电热恒温培养箱
(3) 各种规格加样器,小玻璃试管,聚苯乙烯珠
(4) 洗瓶、抽滤装置等
(四) 注意事项
1. 洗涤要彻底,以免因血清中其他来源的过氧化物酶类物质所产生的非特异性反
应,而影响测定结果。
2. 实验中,应分别设置阳性、阴性、空白对照来控制实验条件,且每份样品均应做三个复管,以保证实验结果的准确性。
3. 为了克服酶标抗体因非特异性吸附而造成的较高本底,可用适量小牛血清加以抑制。
4. 当加入luminol后,迅速产生化学发光并使发光在一秒钟内达到峰值,犎;后很快衰减到基线水平。因此,只有当小试管置于仪器的测量位置时,方可加入luminol。
5. 底物的加入,是为了增强化学发光强度。但只有当底物分子与酶催化活性中心充分接触时,反应速度才能加快。当反应进行15min达到平衡时,牷/学发光强度则不再随时间的延长而变化,且在1h内保持稳定,因此,控制底物与酶反应15min后加luminol进行化学发光测定。
暂无品牌问答